ViewSonic 35 PJD6220/PJD6230/PJD6240
RS-232 Command and Conguration
RS232 Serial Remote Control Command
Item Description Comment
Baud Rate 19200
Parity Bit none
Data Bit 8
Stop Bit
1
Assign Port COM1
Power On Command
Send String BE, EF, 10, 05, 00, C6, FF, 11, 11, 01, 00, 01, 00
Response 06
Comment
Power Off Command
Send String BE, EF, 03, 06, 00, DC, DB, 69, 00, 00, 00, 00, 00
Response 06
Source Command
Send String BE, EF, 02, 06, 00, 57, D0, 2E, 00, 00, 00, 00, 00
Response 06
Comment
Auto-Sync Command
Send String BE, EF, 02, 06, 00, 86, D1, 2F, 00, 00, 00, 00, 00
Response 06
Comment
Menu(for OSD) Command
Send String BE, EF, 02, 06, 00, E9, D3, 30, 00, 00, 00, 00, 00
Response 06
Comment
Up (for OSD) Command
Send String BE, EF, 02, 06, 00, 6D, D2, 34, 00, 00, 00, 00, 00
Response 06
Comment