- 76 -
www.vivotek.com
T: 886-2-82455282
F: 886-2-82455532
seqop
0/1 Enable/Disable sequential operation
sinter
1 ~ 99999 Interval of sequential snapshot in second
mail Send snapshot by e-mail
smethod
ftp Send snapshot by ftp
suffix
0/1 Enable/Disable FTP put snapshots with date and
time suffix
resetdo
0/1 Reset/No reset DO when click save button
Example: Enable sequential send snapshot by every 1 second with email.
http://myserver/setup/app.vspx?method=set&exclude=1&eventop=0&seqop=1&
smethod=mail&sinter=1
Drive the digital output
Note: This request requires the privilege of I/O access control.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is H, L. H means NC (normal close) connected with COMMON and L
means NO (normal open) connected with COMMON. The number of DO dependents
on the server type.
parameter Value description
H – NC connected with COMMON
do<num>
<state>
L – NO connected with COMMON