SPECIFICATION
WHISTLER 1200 WATT INVERTER SPECIFICATIONS
Maximum Continuous Power……………………………1200 Watts
Maximum Surge Capability (Peak Power).....................2400 Watts
**
No Load Current Draw………………………………...............< 1.3A
Waveform……………………………….............Modified Sine Wave
Operating Input Voltage Range…………….....11-15+0.5 Volts DC
AC Receptacle……………………..............Dual 3 Prong Grounded
Approximate Dimensions........................ 11.3” L x 5.9” W x 2.7” H
Approximate Weight………………...................……………..4.2 lbs
WHISTLER 2000 WATT
INVERTER SPECIFICATIONS
Maximum Continuous Power…………........................…2000 Watts
Maximum Surge Capability (Peak Power).................... 4000 Watts
**
No Load Current Draw…………………………...............…....< 2.0A
Waveform…………………………...............…..Modified Sine Wave
Operating Input Voltage Range………….........11-15+0.5 Volts DC
AC Receptacle…………………..................Dual 3 Prong Grounded
Approximate Dimensions….....................13.5” L x 8.7” W x 3.4” H
Approximate Weight………………..............……………….9.0 lbs
WHISTLER 3000 WATT
INVERTER SPECIFICATIONS
Maximum Continuous Power……………........................3000 Watts
Maximum Surge Capability (Peak Power).....................6000 Watts
**
No Load Current Draw……………………………...............…< 3.0A
Waveform…………………………….................Modified Sine Wave
Operating Input Voltage Range………….....…11-15+0.5 Volts DC
AC Receptacle…………….4 x 110V/120V AC (3 Prong Grounded)
Approximate Dimensions……................ 15.2” L x 9.3” W x 6.3” H
Approximate Weight……………………....……………..........14.9 lb
**
Under certain conditions your inverter may provide up to 2
times the continuous rating for a brief period.
29
TROUBLESHOOTING
28
Overload or High Temp LED on
Problem Solution
Equipment has a high Turn inverter power switch
start up surge. OFF (O) and then ON (l)
again until the inverter
powers your appliance.
Repeat as necessary
to get your appliance
"started".
Battery voltage below Recharge or replace
10 volts. battery.
Equipment being operated Use a higher capacity
draws too much power. inverter or do not use this
equipment.
Inverter is too hot (thermal Allow inverter to cool.
shutdown mode). Check for adequate
ventilation. Reduce the
load on the inverter to
rated continuous power
output.