Whistler PRO-3000W Power Supply User Manual


 
FEATURES
1. Three 110 AC Outlets
2. Remote Operation Jack
The inverter is designed to be operated from a
remote location via a WHISTLER Remote Control
Switch (P/N Pro-RS01) which plugs into this socket.
This optional accessory is available through
WHISTLER or your WHISTLER dealer.
3. USB Power Port
This port is always on and independent of the
inverters on/off switch.
4. On/Off Switch
Turns the unit On/Off.
5. Digital Power Meter
6. On/Shutdown Indicator Light
The LED will illuminate GREEN when the inverter is
powered in normal conditions. This light will turn RED
and the inverter will automatically shut down (except
low voltage alarm) when any of the following
problems occur:
• Short Circuit Protection.
The inverter will shut
down until the short is removed.
• Low Voltage Alarm. An alarm will sound when the
voltage from the battery discharges to 10.5+/-0.5
volts DC. This is an indication that the battery needs
to be recharged.
• Over Voltage Protection. The inverter will turn itself
off when the input exceeds 15.5+/-0.5 volts DC.
• Under Voltage Protection. The inverter will turn
itself off when the input is less than 10.0+/-0.5
volts DC.
FEATURES
• Overload Protection. The inverter will turn itself off
when the continuous draw or the surge draw of the
equipment being operated exceeds the maximum
power rating for the inverter.
• Thermal Protection. The inverter will turn itself off
when the internal temperature exceeds safe design
parameters.
7. Cooling Fans
8. Power Input Terminals
(Observe proper polarity)
Note:
In the event of an automatic shut down or continuous
audible alarm, turn the inverter OFF (O) until the source of the
related problem has been determined and resolved.