Charge Control or Diversion Control Indications
(Green)
The flashing rate of the LED indicates the controller’s stage
of operation and approximate battery voltage.
One to four flashes indicates the controller is in the Bulk
stage. As the flashing rate increases, the batteries are
progressively closer to the Bulk voltage. Table 3-1
indicates the approximate level the battery is below the
Bulk setting.
Five flashes indicates the controller has reached Bulk
voltage and is in the Absorption stage.
Solid green means the controller is in the Float stage and
is regulated at the Float voltage.
Table 3-1
Battery Voltage LED Indicators
Green LED
(Charge/Diversion Mode)
LED
Status
Red LED
(Load Control Mode)
Battery at FLOAT Setting
Always
ON
Battery at LVD Setting
(for 6 minutes = LVD)
Battery at BULK Setting
5 blinks
> 0.15
above
LVD
>0.03
above
LVD
>0.45
above
LVD
BULK Setting Minus (–) LVD Setting Plus (+)
0.25 Vdc 0.50 Vdc 1.00 Vdc 4 blinks 0.15 Vdc 0.30 Vdc 0.45 Vdc
0.50 Vdc 1.00 Vdc 2.00 Vdc 3 blinks 0.30 Vdc 0.60 Vdc 0.90 Vdc
0.75 Vdc 1.50 Vdc 3.00 Vdc 2 blinks 0.45 Vdc 0.90 Vdc 1.35 Vdc
> 0.75
below Bulk
> 1.50
below Bulk
> 3.00
below Bulk
1 blink > 0.45
below Bulk
> 0.90
below Bulk
> 1.375
below Bulk
12 volts 24 volts 48 volts DC
Voltage
12 volts 24 volts 48 volts