Xantrex Technology TFB350C Printer Accessories User Manual


 
Installation Guide
6
©2002 Xantrex Technology Inc. All Rights Reserved
P/N 973-0019-01-02 Rev A 06/2002
Installation
Mounting
Locate the fuse block within 18 inches (45 cm) of the
battery. It should be placed in a location where it is
easily accessible should the fuse need replacing.
1. Squeeze the clear plastic protective cover and
remove it from the fuse block base.
2. Use the fuse block base as a template for location of
the four mounting holes. The fuse block should be
mounted to a secure surface. Allow at least 6 inches
(15 cm) from the fuse contacts to allow for removal
without shorting to a grounded object.
3. Use appropriate hardware (not supplied) to mount
the fuse block.
7.0" (177.8 cm)
6.250" (158.75 cm)
2.00"
(50.6 cm)
X4 holes for #10 screws
1.32"
(33.53 cm)
A
A
BB
Figure 2
Fuse Block Dimensional Drawing
(Not to scale)
Table 1
Bolt and Nut Sizes
NOTE: It is not
recommended to
locate the fuse
block inside the
enclosure with
the batteries
where explosive
gases may exist.
epyTkcolBesuF
)tun/tlob(xxxBFT
)wercstes(CxxxBFT
eziSguL/tloB
AB
002,011BFTtunxehhtiwtlob81-8/3tunxehhtiwtlob01-61/5
004,053,003BFTtunxehhtiwtlob81-8/3tunxehhtiwtlob81-8/3
C002,C011BFTselbactuc0/2-4#rofsgul0/2#tunxehhtiwtlob01-61/5
C004,C053,C003BFTselbactucMCM052-4#rofsgulMCM052tunxehhtiwtlob81-8/3