All measurements were made on products performing within established operating specifications and received
recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for
safety and emissions.
www.xerox.com
Reference “About Xerox”
Product: DocuColor 2006CP PSDS No: 0861
Section V - Emission/Exposure Information*
Light Source FDA Accession #
FDA registered laser in a Class 1 Laser System 9820515-03
Electromagnetic Emissions
US FCC: Class A, Token Ring Class A
Canada DOC: Class A, Token Ring Class A
Audible Noise TLV
Run 52.9 dB(A) 85.0 dB(A)
Standby 35.7 dB(A)
Impulse 66.7 dB(A)
Ozone
Concentration Based on Simulation Model:
Daily Copy Volume 136 copies/ hours
Room Size 8 m
3
1/2 Air Room Change per Hour
0.01 mg/m
3
TLV
0.005 ppm 0.1 ppm
Total Dust TLV
.012 mg/m
3
10 mg/m
3
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American
Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration.
These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time-
Weighted Average) for a normal eight-hour workday.