Xerox 6115 Copier User Manual


 
Installation Preparation Document (for physical installation of the product only)
Xerox DocuTech 6100/6115/6135
701P43857
June 2005
Please ensure electrical, space, and supplies are available prior to equipment delivery.
Physical requirements
The DocuSP Controller Monitor and Keyboard are designed to
be positioned on top of the DocuTech 61XX printer. The
controller platform is designed to either be mounted in a stand to
the left of the printer, or to be positioned on the floor to the left of
the printer.
Warning: Due to safety requirements, under no circumstances
should the user interface be visually separated from the printer
module. All system installations must enable mobility of the user
interface to within 30” (760 mm) of the printer for service and
customer maintenance actions
.
Environmental Requirements
Min. Max.
Temperature 50
o
F 85
o
F *
Humidity 30% RH 60% RH
Heat Emission - with
Binder On
22,165
BTU/Hr
14,185 BTU/Hr
(With Vent Kits)
Heat Emission - with
Binder Off
21,265
BTU/Hr
13,609 BTU/Hr
(With Vent Kits)
Power Consumption
Printer/Finisher w/ Binder
On
1,330 Watts
(Standby)
5,890 Watts
(Running)
Power Consumption
Printer/Finisher w/Binder
Off
1,000 Watts
(Standby)
5,630 Watts
(Running)
* The system will inhibit software problems and shut down above 90
o
F
Operating Supplies
Reorder No. Impressions / Unit
Dry Ink 6R206 220K/Carton at 6%
area coverage
Developer 5R161 750K / Carton
Fuser Agent 8R2955 250K / Bottle
Stitcher Wire 8R1174 32K / Roll
Binder Tape - Black 8R2928 425 Binds / Reel
Binder Tape – White 8R3601 425 Binds / Reel
Binder Tape – Gray 8R3602 425 Binds / Reel
Binder Tape – Blue 8R3603 425 Binds / Reel
Binder Tape – Brown 8R3604 425 Binds / Reel
Binder Tape – Red 8R3824 425 Binds / Reel
The Xerox Supplies Marketing Center, 1.800.822.2200, is available
for ordering Xerox supplies, including paper and other thruput
material.
Network Requirements
The Ethernet interface on the DocuSP controller is a 10/100-
MB/sec twisted pair standard (10BaseT).
The Ethernet connection to the DocuSP controller must be
compatible with the Institute of Electrical and Electronics
Engineers (IEEE) 802.3 standard. (The physical form of this
connecter is RJ45 and must be correctly wired.)
The DocuSP controller supports TCP-IP, SPX,/IPX, and
EtherTalk Link Access Protocol (ELAP) protocols if the proper
gateways are installed on the controller.
The DocuSP controller does not provide Novell
Server network
services. To use the SPX/IPX protocol, a Novell server installed
on the network is required.
A Xerox Token Ring solution is available for the 61XX family.
When Token Ring is installed, it becomes a Token Ring
only
connectivity solution. The NetWare gateway and AppleTalk
gateway will not function, and the built in Ethernet bge0 twisted
pair interfaces are disabled. (Gigabit Ethernet is supported with
a Sun controller card – some customers have asked for this
option.)
Telephone Requirements
A voice telephone line is required where the DocuTech 6100, 6115,
6135, is installed.
Voice line will be used when the operator, administrator, or Xerox
Service Personnel is asked to read the screen information from the
DocuSP controller dialogs to Xerox Customer Support or Technical
Support Center Personnel.
Position / Performance at Maturity
Average
Monthly
Service
Calls
8
7
6
5
4
3
2
1
Average Monthly Copy Volume
300K 1M 2M
Optimum Range
500K 1.5M
Note:
This product is targeted for the 300K to 2M copies per month market
segment. Usage above this range may result in a higher service
frequency