Xerox FIB1-SERIAL Network Router User Manual


 
Application
CISPR PUB.22 Class A COMPLIANCE:
This device complies with EMC directive of the European Community and meets or exceeds the following
technical standard. EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of
Information Technology Equipment. This device complies with CISPR Class A.
WARNING:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
CE NOTICE
Marking by the symbol CE indicates compliance of this equipment to the EMC directive of the European
Community. Such marking is indicative that this equipment meets or exceeds the following technical standards: EN
55022:1994/A1:1995/A2:1997 Class A and EN61000-3-2:1995, EN61000-3-3:1995 and
EN50082-1:1997
WARNING:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and if not installed and used in accordance with the instruction manual may cause harmful
interference in which case the user will be required to correct the interference at his own expense. NOTICE: (1) The
changes or modifications not expressively approved by the party responsible for compliance could void the user's
authority to operate the equipment. (2) Shielded interface cables and AC power cord, if any, must be used in order to
comply with the emission limits.
TRADEMARKS
Ethernet is a registered trademark of Xerox Corp.
ST
®
is a registered trademark of AT&T.
Six-screws Terminal Block
Environment
Temperature : 0-50℃(operating)
-20℃- 70℃ (storage)
Humidity 10-90% non condensing
Dimension
138mm x 86mm x 20mm
(H x W x D)
Weight : 300g
Power
+12V / 1A maximum
DC plug type : center Positive
72
5
3
8
2
9
DB9
Female
3
4
1
5
6
PIN
NO #
FIB1-SERIAL Pin Assignment
(DB9 Connector for Option)
Fiber Optic Connectors
Two connectors are provided for fiber optic cable connection.
One is for transmission and the other is for reception of optical data. (WDM transceiver has only on SC
connector for bi-directional transmissions on a single fiber)