Z-Com R2 Extender Network Router User Manual


 
Connect Up
Before installing the Ethernet cable with a waterproof RJ-45 connector, it is recommended that
the Cat-5 RJ-45 coaxial cable be used for the bridge to power injector connections.
1. To connect to the hole labeled PoE+Data, open the black cover in advance by using a
coin or a slotted screwdriver and then screw in the body of the gland and tighten.
2. Slide the sealing nut to the RJ-45 cable from its middle breach and then insert the sealing
into the cable.
Slide the Sealing Nut from its Breach
3. Insert the RJ-45 connector and make sure that the locking tab snaps home.
R2 Extende
r
RJ-45 Port
4. Screw the sealing on the gland and tighten.
Chapter 5 Troubleshooting Page 9