HDSL2 for General Distribution Installation and Maintenance Practice Control Port Operation
61223HDSL2L2-5B 35
Alarm History
The Alarm History screens are divided into three separate screens:
“T1 Alarm History” on page 35
“HDSL2 Span History” on page 36
“HDSL2 Facility Alarm History” on page 37
T1 Alarm History
The T1 Alarm History screen (Figure 35) displays the following information:
DSX-1/DS1 Red Alarm
DSX-1/DS1 Yellow Alarm
DSX-1/DS1 Blue Alarm
Figure 35. T1 Alarm History Screen
Circuit ID:HNTSVLALHDSL2 03/01/05 09:29:45
Press ESC to return to previous menu
T1 Alarm History
LOCATION ALARM FIRST LAST CURRENT COUNT
--------------------------------------------------------------------------------
H2TU-C RED(LOS/LOF) 01/01/00 00:00:04 01/01/00 00:00:04 Alarm 002
(DSX-1) YELLOW(RAI) OK 000
BLUE(AIS) OK 000
H2TU-R RED(LOS/LOF) 01/01/00 00:14:05 01/01/00 00:14:05 Alarm 001
(DS1) YELLOW(RAI) OK 000
BLUE(AIS) OK 000
--------------------------------------------------------------------------------
1. T1 Alarm 2. HDSL2 Span 3. Facility Alarm C. Clear T1 Alarm
Selection: