Error Message CFGMGR-6-UNABLE_TO_NVGEN_RUNNING_CFG: config file too large...
Note This message applies only to Catalyst 3750 and 2975 switches.
Explanation The stack master is unable to generate the stack running configuration because the
configuration file is too large.
Recommended Action Remove some configuration commands.
CMP Messages
This section contains the Cluster Membership Protocol (CMP) messages.
Error Message CMP-4-MEM_CMPIP_ADDR_CONFLICT: Conflict with CMP IP address
[IP_address], Reissuing a new CMP IP address to member [dec]
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 2960 switches.
Explanation The cluster commander found a conflict with the assigned CMP IP address of the
member. A new unique CMP IP address is assigned to the member. [dec] is the member number.
Recommended Action This is only a warning message. The commander has already assigned the
cluster member a new unique address. Clear any open TCP connections on the member by using
clear tcp privileged EXEC command.
Error Message CMP-5-ADD: The Device is added to the cluster (Cluster Name: [chars],
CMDR IP Address [IP_address]).
Explanation The device is added to the cluster. [chars] is the cluster name, and [IP_address] is the
Internet address of the command switch.
Recommended Action No action is required.
Error Message CMP-5-MEMBER_CONFIG_UPDATE: Received member configuration from member
[dec].
Explanation The active or standby command switch received a member configuration. [dec] is the
member number of the sender.