Send documentation comments to mdsfeedback-doc@cisco.com.
Chapter 2 Installing the Cisco MDS 9216 Switch
Starting Up the Switch
2-20
Cisco MDS 9216 Switch Hardware Installation Guide
78-16165-01
Caution Do not operate the switch without a functioning fan module except for during the
brief fan module replacement procedure. The Cisco MDS 9000 Family switches
can operate for only a few minutes without a functioning fan module before they
begin to overheat.
Step 9 When the switch has finished booting, verify that the LED behavior is as follows:
• Fan module: Status LED is green
• Power supplies:
–
Input Ok LED is green
–
Fan Ok LED is green
–
Output Fail LED is off
• Supervisor, switching, or services modules:
–
The System LED on the supervisor module is green, indicating that all
chassis environmental monitors are reporting that the system is
operational. If this LED is orange or red, then one or more environmental
monitors is reporting a problem.
–
The Status LED on the switching or services modules flashes orange
once, remains orange during diagnostic boot tests, then turns green when
the module is operational (online). If the system software is unable to
start up, this LED remains orange or turns red.
Note The LEDs for the Fibre Channel ports remain orange until the ports are
enabled, and the LED for the MGMT 10/100 Ethernet port remains off
until the port is connected.
If any LEDs other than the Fibre Channel port LEDs are orange or red after the
initial boot processes are complete, refer to Appendix A, “Troubleshooting” for
more information.
Step 10 If a component is not operating correctly, try removing and re-installing it. If it
still does not operate correctly, contact your customer service representative for