Chapter 4: Programming Commands88
Revision D 12/09
A799-PG00001D
Cash drawer status (n = 2 or n = 50)
Bit O/On Hex Decimal Status for transmit status
0 O 00 0 One or both cash drawers
open.
On 01 1 Both cash drawers closed.
1 O 00 0 One or both cash drawers
open.
On 02 2 Both cash drawers closed.
2 – – – Undened
3 – – – Undened
4 O 00 0 Not used. Fixed to o.
5 – – – Undened.
6 – – – Undened.
7 O 00 0 Not used. Fixed to o.
Flash memory user sector status (n = 4 or n = 52)
Bit O/On Hex Decimal Status for transmit status
0 – – – Undened. Fixed to o.
1 – – – Undened. Fixed to o.
2 O 00 0 User data storage write successful
On 04 4 User data storage write failed, specied area not erased.
3 O 00 0 Flash logo area adequate, denition stored
On 08 8 Flash logo area not adequate
4 O 00 0 Not used. Fixed to o.
5 O 00 00 No thermal user-dened characters
written to ash.
On 20 32 Thermal user-dened characters written to ash.
6 O 00 0 Not used. Fixed to o.
7 – – – Undened.
Exceptions
When n is out of the specied range, the command is ignored.
Send printer software version
ASCII AX V
Hexadecimal 1F 56
Decimal 31 86
The printer returns 8 bytes containing the boot and ash software version. The rst 4 bytes returned are an ASCII string for
the boot version.
The second 4 bytes are an ASCII string for the ash version. Example: For 1.234.56 (8 bytes), the boot version is 1.23 and
the ash version is 4.56.