A SERVICE OF

logo

STREETWORKS Outdoor Lighting Solutions 145Cooper Lighting
CFB UTILITY FLOOD FLOODLIGHTING
DRILLING PATTERN FOR YOKE- AND TRUNNION-MOUNT
YOKE MOUNT TRUNNION MOUNT
3 3/4" [95mm]
1 7/8"
[48mm]
7/8" [22mm]
dia. hole
1"
[25mm]
9/16" [14mm]
dia. hole (2)
PHOTOMETRICS [Complete IES files available at www.cooperlighting.com]
2" [51mm]
1 1/2" [38mm]
5 3/8"
[137mm]
3 1/2"
[89mm]
ACCESSORIES
OA1197 OA1198 OA1199
CFB40S76.IES
400-Watt HPS
50,000-Lumen Lamp
Tilt-45° Angle
A
B
C
D
E
01234
1
0
1
2
3
4
5
6
7
1234
CFB40M76.IES
400-Watt MH
36,000-Lumen Lamp
Tilt-45° Angle
01234
1
0
1
2
3
4
5
6
7
1234
A
B
C
D
E
FOOTCANDLE TABLE
Select mounting height and read across for footcandle values of each
isofootcandle line. Distance in units of mounting height.
Mounting Footcandle Values for
Height Isofootcandle Lines
ABC D E
CFB40S76.IES
25' 2.88 1.44 0.72 0.36 0.14
30' 2.00 1.00 0.50 0.25 0.10
35' 1.50 0.75 0.37 0.19 0.07
40' 1.12 0.56 0.28 0.14 0.06
CFB40M76.IES
25' 2.88 1.44 0.72 0.36 0.14
30' 2.00 1.00 0.50 0.25 0.10
35' 1.50 0.75 0.37 0.19 0.07
40' 1.12 0.56 0.28 0.14 0.06