DCP42‐en‐GB_V1.512/14
19
11. Troubleshooting
OUP:OverVoltageProtection
Thisunithasabuilt‐intrackingovervoltageprotectionfeature.Intheeventofoutputvoltage
becominggreaterthanthesetvalue(seespecifiedrangefromspecificationstable),protection
willbetriggeredandtheoutputpowerwillbecutoffandOUPwarningappearsasbelow.
Toresetthewarning,switchofftheunitandremoveallloading.
Switchtheunitbackonagainanditshould resumenormaloperation.
Ifthisproblempersists,pleasecontactthecustomercaredepartmentorthepointofpurchase.
OTP:OverTemperatureProtection
Thereisathermosensorinsidetheunittomonitorandpreventtheunitfromundulyheating
internally.WhenanOTPerroroccurs,thereisnooutputandthefollowingwarningwillappear
ontheLEDdisplay.
Whenthiswarningappears,switchofftheunitandremoveallloading.
Checktheloadandoutputsetting.Allowtheunittocoolforatleast30minutes.
Checktoseeifanyventilationholesareblocked,alsocheckthatthereissufficientclearance
aroundthepowersupply.
Listencarefullyfortheshortwindsoundemanatingfromthecoolingfanwhentheunitis
switchedONagain.Ifthewindsoundisnotdetected,thefanmaybefaulty;donotusethe
powersupplyinthiscase,contactthecustomercaredepartmentortheagentfromthepointof
purchase.
OCP:OverCurrentProtection
NormallytheoverloadprotectionissustainedbytheCCconstantcurrentmode.WhentheCC
modefailsandgoesundetected,seriousdamagetothetestpieceorloadmayoccur.TheOCPis
usedtominimizetheextentofdamagetotheloadsintheeventofpowersupplyfailure.
Switchoffthepowersupplyassoonasthiswarningisseen(asshownbelow).
Toresetthiswarning,removeallloadingandpresstheOUTPUTON/OFFbutton.
Switchtheunitbackonagainanddoublecheckwithcaution.
Ifthisproblempersists,pleasecontactthecustomercaredepartmentorconsultwiththeagent
atthepointofpurchase.
Copyright©2014FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com