SPA 12 AAP Speaker • Installation Guide
SPA 12 AAP Installation Guide
SPA 12 AAP Speaker • Specifications, part numbers, accessories 76
The magnet cap and rear enclosure pieces work best with
mounting options where ample room is provided for them.
Some four-space AAP architectural frame products are too small
to allow for these optional pieces, and some wall mount
situations may present an obstruction. In such instances,
remove the magnet cap.
To remove the magnet cap
1. Unscrew the two ¼” lock washer nuts that hold the
magnet cap in place.
2. Gently pull the magnet cap from the speaker driver.
Although the SPA 12 AAP speaker works properly in free air
(without the rear enclosure and magnet cap), it is a good
practice to limit open space behind the SPA 12 AAP. Cover
large openings as much as possible to optimize the speaker’s
performance.
To install the SPA 12 AAP speaker into an Extron architectural
frame, do the following. Several of the steps are summarized in
figure 4, below.
1. Insert the SPA 12 AAP speaker and front grill into the four-
space AAP opening of the architectural frame. Ensure that
the SPA 12 threaded standoffs are lined up with the
openings of the architectural frame.
C
O
N
F
I
G
P
R
O
J
E
C
T
O
R
V
O
LU
M
E
1
2
3
4
O
N
O
F
F
4-gang
Wall Box
Extron
MLC 104 AAP
Front Grill
Extron
SPA 12
S
P
A
1
2
A
A
P
Tighten (4) #4-40 Nuts
w/ Captive Washers
Speaker Wire
1
2
3
Figure 4 — Mounting the SPA 12 into an MLC 104
2. Attach #4-40 nuts to both pairs of threaded standoffs
emerging from the SPA 12, and tighten them to the
architectural frame.
3. Attach the speaker wire pair ends to the SPA 12 AAP
speaker by soldering the exposed tips to the speaker’s
positive and negative terminal pair (marked – +).
4. Attach the opposite end of the speaker wire to the output
of your amplifier.
Specifications
Audio/acoustic and electrical
Speaker type ................................. 1-way, full range architectural speaker
Frequency range .......................... 350 Hz to 15 kHz, -10 dB, half space
Power capacity ............................. 10 W continuous program
5 W continuous pink noise
Nominal sensitivity ..................... 86 dB SPL, 1 W (2.83 V) @ 1 m, half space
Nominal impedance .................... 8 ohms
Nominal coverage ....................... 150° conical coverage
Driver ............................................ 2.5" (64 mm) full-range
Input connector ............................ (1) solder terminal, 2 pin
General
Package ......................................... 1 speaker
Temperature/humidity .............. Storage: -40 to +158 °F (-40 to +70 °C) /
10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) /
10% to 90%, noncondensing
Mounting ...................................... Mountable into the four-space AAP
opening of an Extron Cable Cubby
(models 300C, 300S, 600, 800); an HSA 400
or HSA 402; or a mounting frame
(AAP 102, AAP 102 FSR, AAP 106 AKM
UK, AAP 104, AAP 202)
Enclosure type .............................. Metal faceplate with plastic rear enclosure
Enclosure
Faceplate ........................... 2.8" H x 3.5" W x 0.1" D (71 mm H x
89 mm W x 3 mm D) (four space AAP
plate)
Device ................................ 2.8" H x 3.5" W x 2.5" D (71 mm H x
89 mm W x 64 mm D)