About the water softener system.
Service: Manually Initiated Electronic Diagnostics
To enter diagnostics, press and hold the
DATA
button until the display appears as shown.
NOTE:
If the softener is in the middle of a regeneration, top part of the display shows the
cycle of regeneration and minutes of the cycle remaining. If two cycle names are flashing,
the valve is in transition between the cycles.
A
The three digits under
WATER MANAGEMENT SYSTEM
indicate water meter operation
as follows:
■000 (steady) = soft water not in use…no flow through the meter.
—OPEN A NEARBY SOFT WATER FAUCET—
■ 000 to 140 (continual) = repeats display for each gallon of water passing through
the meter.
If you don’t get a reading in the display, with faucet open, pull the sensor from the valve
outlet port. Pass a small magnet back and forth in front of the sensor. You should get a
reading in the display. If you get a reading, shut off water supply, unhook the in and out
plumbing and check the turbine for binding.
B
This display segment ( ), in the following chart, indicates an open POSITION
switch. Use the
TOUCH or HOLD
button to manually advance the valve into each cycle and
check correct switch operation.
Press the
DATA
button again. This diagnostic display shows the total number of recharges
(top) since the timer was connected to electrical power.
The number of days since the timer was connected to electrical power is shown in the
bottom part of the display. If over 1999 days, a (x10) indicator shows, meaning you must
multiply the number shown by 10.
Press
DATA
once again to return the present time to the display.
3
2
1
CORRECT SWITCH
DISPLAYS VALVE CYCLE STATUS
Valve in service, fill, brining, backwash
or fast rinse position.
Valve rotating from one position to another.