Setup
12 3A0096B
Setup
Tighten Clamps
See FIG. 4. Before starting, torque the screws (3) secur-
ing the four clamps (4) to 21-25 ft-lb (28-34 N•m).
Wet Cup
See FIG. 5. Before starting, fill the wet cup (P) 1/3 full
with Graco Throat Seal Liquid (TSL) or compatible sol-
vent.
NOTE: The wet cup has a covered fill port fitting. A plug
(9) is shipped loose with the pump and can be installed
in place of the covered fitting if desired.
Wet Cup Drain Fitting
As supplied, the side port of the wet cup is plugged. To
install a drain tube, remove the plug and install the sup-
plied 90° tube fitting (R) in its place. Attach a 1/2 in. (13
mm) ID flexible plastic tube (not supplied) to the fitting to
drain any overflow to a pail.
Torque Wet Cup
MaxLife pumps use a special u-cup throat seal that is
non-adjustable and does not require periodic torquing.
F
IG. 4. Wet Cup
3
ti14668a
1
Torque to 21-25 ft-lb (28-34 N•m).
1
FIG. 5. Wet Cup
P
ti14667a
9
R