Standby
312062W 37
Standby
If you stop spraying for a period of time, the
unit will enter standby by shutting down the
electric motor and hydraulic pump, to reduce
equipment wear and minimize heat buildup.
The ON/OFF LED and the pressure/cycle dis-
play on the motor control panel will flash when
in standby.
To restart, spray off target for 2 sec. The sys-
tem will sense the pressure drop and the motor
will ramp up to full speed in a few seconds.
To activate or disable standby, adjust DIP
switch #3 on the motor control board. See
Reactor Repair-Parts manual 312063.
The idle time before entering standby is
user-settable as follows:
1. Turn main power switch OFF .
2. Press and hold , then turn main power
switch ON .
3. Press or to select desired timer
setting (5-20, in 5 minute increments). This
sets the length of inactive time before the
unit will enter standby.
4. Turn main power switch OFF to
save changes.
The , , and heat zones
will not be shut off in standby.
This feature is disabled from the factory.