A SERVICE OF

logo

Chapter 2
Installing and Using Monitors
Checking for Special Requirements
30
Checking for Special Requirements
Some devices have special requirements in order to be monitored. Examine the tables of supported products
below to see if any of your devices have special requirements.
Table 2-1 Disk Arrays
Product
Model/Product
Number
Special
Requirements
HP AutoRAID Disk Array
Supported by: AutoRAID Disk Array
Monitor
12H
12
Requires the
following ARMServer
versions:
HP-UX 10.XX
(PHCO_23261);
HP-UX 11.00
(PHCO_23262);
HP-UX 11.11 (Patch
PHCO_23263)
HP High Availability Disk Array
Supported by: High-Availability Disk
Array Monitor
30/FC
20
10
None
HP Fast/Wide SCSI Disk Array
Supported by: Fast/Wide SCSI Disk
Array Monitor
C243XHA None
HP Fibre Channel High Availability
Disk Array (Model 60/FC)
Supported by Disk Array FC60 Monitor
HP SureStore E
Disk Array
FC60
HP-UX 10.20
(PHCO_26822);
HP-UX 11.00
(PHCO_26823);
HP-UX 11.11
(PHCO_26824)
HP Storage Works Modular SAN array
1000
Supported by: HP Storage Works
Modular SAN array 1000 Monitor
HP Storage
Works Modular
SAN array 1000
None