A SERVICE OF

logo

Physical and operating specifications 93
Table 12 Hardware Specifications
Item Components
Power Supply unit (PSU) 750 W or 1200 W redundant, power supply
Thermal solution Four system fans
Table 13 Physical Dimensions
Item Description
System board platform EATX (Extended Advanced Technology Extended)
System board dimension 12” x 13” (304.8 mm x 330.2 mm)
Server dimensions
Rack
448W x 87.9H x 714.7D (mm)
Server weight Basic configuration ( excludes monitor): TBD kg
Table 14 Environmental Specifications
Item Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35° (+50 to +95°F)
-30 to 60° (-22 to 140°F)
-30 to 60° (-22 to 140°F)
38.7° (101.7°F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr
LWad: 6.7 Bels
(operating at room temperature)
LWad: 6.7 Bels
(Idle at room temperature)
Table 15
Power Supply Specifications
Item Description
Dimensions (H x W x L) 1.515” (H) x 3.4” (W) x 7.736” (L) excluding card
edge connector.
Weight (approximate)
3 pounds