Data Format Editor
Data Formatter
When Data Formatter is turned off, the barcode data is output to the host as read (including prefixes and
suffixes). Choose one of the following options.
Default = Data Formatter On, but Not Required.
When Data Formatter is required, all input data must conform to an edited format or the document
reader does not transmit the input data to the host device.
Alternate Data Formats
Alternate formats allow you “single shot” capability to scan one barcode using a different data format
than your primary format. When data formats are programmed (see page 5-1), you must input whether
you are programming the primary format, or an alternate format numbered 1, 2, or 3.
Enter Data Format
* Default Data Format
Clear One Data Format
Save
Discard
Clear All Data Formats
Data Formatter Off
* Data Formatter On,
but Not Required
Data Format On, Format Required