![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/4/a2/4a26c418-5f26-4a08-b7b4-240ef513e59c/4a26c418-5f26-4a08-b7b4-240ef513e59c-bg8.png)
3
1995-1997 - INLINE, INC PATHFINDER OPERATION MANUAL - REV2.1A May 19, 1997
SWITCHING - CONNECTING INPUTS AND OUTPUTS (FRONT PANEL)
The switching menu is called the PATH Config menu, and it functions as follows:
The diagram above shows the LCD readout for the PATH Config menu. The actual readout will vary
depending on the number of inputs and outputs your unit has. The bottom line of the LCD display shown
above,
INxx/yy>OUTjj/kk," reads as follows: Input xx of yy is connected to output jj of kk, where:
Ga: The selected group is Group a. a ranges from 1 to 6. (see Board Configuration on page 13 for
more details.)
Sb: The selected setup memory is b. b ranges from 1 to 8 (see Saving and Recalling Setup
Memories on page 5 for more details.)
xx: The selected input.
yy: The total number of inputs available.
jj: The selected output.
kk: The total number of outputs available.
Use the Up and Down Scroll button
to select the output you would like
to change.
Use the number buttons to enter the number
of the input you would like to connect to the
selected output. It is always best to enter a
two digit number, such as 03 or 12.
Use the ENTER/SELECT button to
confirm a switch. This button executes the
switch selected.