25
GB
W Align the depth of the unit door Z :
- top: loosen screws dr�
- at the bottom: loosen the hexagonal
screws dq with the ring spanner sup-
plied ds and adjust the door.
- Allow an air gap of approximately 2 mm
between the unit door and the body of
the unit. Do not allow any burls or seal-
ing lips to touch - this is important for
correct function!
W For large unit doors, fit a third pair of fas-
tener brackets dp.
To do this use the predrilled holes in the
handle area of the appliance door.
W Check that the doors are correctly seated and adjust if nec-
essary. Tighten all screws.
- Tighten the lock nuts dn with the ring spanner ds hold the
adjusting bolts do with a screwdriver as you do so.
W If necessary, adjust the shim cl by pushing it parallel to the
floor of the unit. It must not protrude.
W Fix the appliance underneath with the plastic bracket cs us-
ing a second screw cu to fasten it into the round hole.
W Fit all the covers:
- Position the upper covers dt and en-
gage them.
- Position the side covers du as far as
the stop, then press the cover until it
engages with an audible click.
- Push the cover el at the side, using a
screw driver, to pull the cover forward so
that it engages correctly.
W You can now adjust the end
stop spring on the doors. Make
the setting as required with the
allen key 5 supplied:
- turn clockwise
= stronger spring force,
- turn counter-clockwise
= weaker spring force (condi-
tion in which supplied).
W Place the rest of the covers on
the hinges
_______________________________________________
The manufacturer is constantly developing and enhancing all
types and models. Please therefore understand that we reserve
the right to make changes to the shape, options and technology
used.