A SERVICE OF

logo

u
To align the unit door in depth Z: Undo the screws
Fig. 25 (36)
at the top and the hex head screws
Fig. 25 (35)
at the bottom using the ring wrench
Fig. 25 (37)
supplied,
then move the door.
u
Do not allow the knobs and sealing lips
to come into contact with the door - im-
portant for function!
u
Set an air gap of 3/32 '' (2 mm) between
the door of the unit and the body of the
unit.
For large unit doors:
u
Fit a 3rd pair of mounting brackets
Fig. 25 (34)
.
u
Use the holes pre-drilled in the handle
area of the appliance door for this pur-
pose.
u
Check the fit of
the door and
re-adjust, if
necessary.
u
Tighten all
screws.
Fig. 26
u
Tighten the locknuts
Fig. 26 (32)
with the ring wrench
Fig. 26 (37)
while bracing the adjusting bolts
Fig. 26 (33)
with a screwdriver.
u
Position the upper cov-
ers
Fig. 27 (38)
and snap
into place.
u
Place the side covers
Fig. 27 (39)
in position,
slide to the limit and then
press until they snap au-
dibly into place.
u
Attach the covers
Fig. 27 (40)
to the side and
then draw them forward
with a screwdriver, so
that they snap properly
into place.
Fig. 27
For a 24 '' (609.6 mm) wide recess:
u
Position the covers
Fig. 9 (6,7,60)
and snap into place.
For a 23-5/8 '' (600 mm) wide recess:
u
Position the covers
Fig. 9 (5,6,7)
and snap into place.
For appliances without a stop mechanism, adjust the
opening resilience:
The opening resilience of the
door can be adjusted if necessa-
ry using the Allen wrench sup-
plied:*
u
For more spring force: Turn
clockwise.*
u
For less spring force (factory
setting): Turn counterclock-
wise.*
u
Attach the remaining covers to
the hinges.*
*
Check the following points to ensure that the appliance has
been installed correctly. Incorrect installation can cause
icing up, the formation of condensate, and malfunctions:
w
The door must close properly.
w
The door of the unit must not touch the body of the unit.
w
The seal at the top edge on the handle side must fit tightly.
To verify this, darken the room, place a flashlight inside
the appliance near the top, and close the door. If you see
light shining through, check the assembly.
7 Connecting the appliance
WARNING
Electrical shock hazard!
u
Start-up should only take place once the appliance has
been installed according to these instructions.
u
Electrically ground appliance.
u
Do not ground to a gas pipe.
u
Check with a qualified electrician if you are not sure the
appliance is properly grounded.
u
Do not have a fuse in the neutral or grounding circuit.
u
Do not use an extension cord or a multiple socket.
u
Do not use a power cord that is frayed or damaged.
WARNING
Electrical shock hazard!
This appliance is equipped with a three-prong (grounding)
polarized plug for your protection against possible shock
hazards. Electrical Grounding Required.
u
Do not remove the round grounding prong from the plug.
u
Do not use a two-prong grounding adapter.
-
Wait 30 minutes up to 1 hour after installation before you
plug in the appliance. This allows the refrigerant and sys-
tem lubrication to reach equilibrium.
-
Make sure incoming voltage is the same as the appliance
rating. A 110-120 Volt, 60 Hz, 15 Amp electrical supply
(20 Amp for side-by-side installations) circuit that is con-
trolled by a circuit breaker or fuse is required.
Connecting the appliance
12