TROUBLESHOOTING & REPAIR
F-23 F-23
SQUARE WAVE TIG 275
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
T1 MAIN TRANSFORMER TEST (continued)
TABLE F.1.
T1 TRANSFORMER VOLTAGES
TEST POINTS ACCEPTABLE VOLTAGES
SECONDARY WINDINGS SECONDARY VOLTAGES
PLUG J8 PIN 1 (LEAD #210)
TO
PLUG J8 PIN 9 (LEAD #209) 18 VAC
PLUG J8 PIN 6 (LEAD #201)
TO
PLUG J8 PIN 4 (LEAD #204) 18 VAC
PLUG J8 PIN 2 (LEAD #231)
TO
PLUG J8 PIN 12 (LEAD #232A) 115 VAC
PLUG J8 PIN 13 (LEAD #211A)
TO
PLUG J8 PIN 14 (LEAD #212) 23 VAC
X1 TO X2 78 VAC
PRIMARY WINDINGS
1
PRIMARY VOLTAGES
H1 TO H2 208 VAC
H1 TO H3 230 VAC
H1 TO H4 460 VAC
NOTE: If the input voltages vary, the secondary voltages will vary accordingly.
1