![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/3/c3/3c3a45a1-1d9a-41c5-957f-51f20937b570/3c3a45a1-1d9a-41c5-957f-51f20937b570-bg10.png)
10 Interpreting the LEDs and Displays
HX1 Multi-Charger User’s Guide E-EQ-HX1CHGROG-B-ARC
Display
There is one display window for each of the four charging bays. The display gives additional
information on the status of the battery in the bay.
Display shows Indicates…
2 digit number
( 00 – 99 )
A two digit number is displayed for the following reasons:
• % Charge – During a normal charging cycle, the display
indicates the percentage of the charge in the battery from 00%
to 99%.
• Charge Cycle Counter – After momentarily pressing the
recalibration button, the display shows the number of times the
battery has been recharged in the Multi-Charger since its last
recalibration.
• Maximum Capacity – When the recalibrate button is held
down while inserting a battery, the display shows the
maximum charge potential in mAh.
Note: Since the capacity is a four digit number, the display
shows the first two digits for 2 seconds then the last 2
digits for two seconds.
1c or 2c
Either 1 (1c) or 2 (2c) recalibration cycles
Blank No battery is present
_ _
The charger was unable to establish communications with the battery.
This can be due to a damaged battery or dirty contacts. Inspect the
battery contacts and ensure they are not damaged. Clean battery
contacts (on the battery and charger) with a cotton swab and alcohol. If
the problem persists, contact LXE Customer Support.
Off The bay is empty or the Multi-Charger is not connected to AC power
FP, Fq or FL
The battery is not charging properly. Contact LXE Customer Service
for assistance.
Hi or Lo
The battery is above (Hi) or below (Lo) the temperature for charging.
After it reaches room temperature, the battery starts charging.
C
The charger has determined the “maximum capacity when full” register
in the battery is not valid. Place the battery into the recalibration cycle
(as described earlier in this section) to reset the register. The charger
selects the 2c recalibration mode.