Installing the server and connecting the peripheral devices Standard 1.07
68 CallPilot
Connecting the server to the ELAN
Introduction
Connect the CallPilot server to the Meridian 1 switch or Succession 1000
system using the ELAN.
Media Access Control address
The Media Access Control (MAC) address is a unique number assigned to
network cards and controllers. The procedure below asks you to record the
ELAN MAC address. The MAC address is recorded on a label affixed to the
back of the chassis.
To connect the server to the ELAN
1 See the diagram on page 65 to locate the ELAN Ethernet connector.
2 Locate the MAC address label on the back of the chassis that identifies
the ELAN controller MAC address.
ATTENTION
This section applies only if the 1002rp server connects
to a Meridian 1 switch or Succession 1000 system.
ATTENTION
For important considerations about using the ELAN in
your network, see the Planning and Engineering Guide
(555-7101-101).
ATTENTION
To comply with EMC radiation requirements, a Class A
hub must be located 10 m (33 ft.) away from the 1002rp
server. Shielded Ethernet cables must be used.