A SERVICE OF

logo

R
Page 8
November 5, 2010
Cumberland Gap Wood Stove
7006-188G
Floor
Protector
Thimble,
12 in (305mm)
Of Brick
Ceiling Joist
Combustible Wall
Airtight
Cleanout Door
Fireclay Flue Liner
With Air Space
Sheathing
Eave
1 in (25mm) Clearance
With Firestop
Rafter
Flashing
Concrete Cap
Outside Air
Termination Cap
Outside Air Rear Vent
Spark Arrestor Cap
Figure 8.3 Interior Prefabricated Chimney
Figure 8.2 Exterior Prefabricated Chimney
Figure 8.1 Masonry Chimney
H. Typical Stove Systems
Stove system with masonry chimney
consists of: Figure 8.1
Stove
Chimney Connector (stove pipe)
Thimble
Masonry Chimney
Hearth Pad Floor Protection
Stove
Chimney Connector
(stove pipe)
Thimble (for exterior
chimney)
Firestops
Insulations Shields
Storm Collar and Flashing
Termination Cap
Hearth Pad Floor Protec-
tion
Stove system with prefabricated metal
chimney consists of: Figures 8.2 and 8.3
Combustible Wall
Floor
Protector
Chimney
Connector
Ceiling Support
Listed Chimney
Maintain 2" (51mm)
Clearance
Listed Cap
Storm Collar
Flashing
*
*
*Refer to Clearances
to Combustibles
Combustible
Ceiling
Joists
Chimney
Connector
To Stove
Ceiling
Support
Specified
Clearance
Attic
Insulation
Shield
Listed
Chimney
Floor
Protector
Chimney
Connector
Combustible
Ceiling
Combustible Wall
Insulated "T"
Flashing
Listed Cap
Maintain 2" (51mm)
Clearance Through Eave
*
*
*
Listed
Chimney Pipe
Chimney
Connector
To Stove
Trim Collar
on Inside
Wall
Combustible Outside Wall
2" (51mm)
Clearance
Listed Chimney
Insulated "T"
Wall Support
Wall Spacer on
Outside Wall
*Refer to Clearances to Combustibles