A SERVICE OF

logo

Manual-4
INTERNAL ADJUSTMENTS
ere are a number of controls inside the CP 64S used to config-
ure the system for specific applications. Access to these controls
is only required once before initial system setup. Do this before
the CP 64S is installed in a rack or wired into a system. Make
sure the power cable is unplugged before removing the top cover
to gain access. Refer to the diagram below for control locations.
ere are five internal switches related to the two Page Inputs.
e dot on the circuit board shows the factory default:
1 Page 1 Phantom Power 15VDC Default: OFF
2 Page 2 Phantom Power 15VDC Default: OFF
3 Page Priority P1, NO, P2 Default: P1
4 Zone 1 Page Sum Pre- or Post-VCA Default: Pre-VCA
5 Zone 2 Page Sum Pre- or Post-VCA Default: Pre-VCA
1 2 Phantom Power is available for both Page Inputs. If
phantom power is required for the intended microphone, then
set the appropriate switch to ON. If a Paging Input Mic / Line pad
switch is set to LINE, Phantom Power is automatically defeated.
3 Page Priority Assign allows you to select one of the Page
Inputs as a Priority Page Input. e Priority Pager overrides the
non-priority Pager in the Zone(s) it is assigned. Note that the
non-priority Pager may still broadcast in any Zone that the Pri-
ority Pager is not assigned to or not currently broadcasting in. Set
the switch to P1 if you wish Page 1 to have priority over Page 2.
If you wish Page 2 to have priority over Page 1, set the switch to
P2. If NO is selected, neither Paging Input has priority and both
Pagers may be active at the same time. is allows the Paging
Inputs to mix for applications like karaoke or PA. If a Page Input
is used for emergency paging, set it as the Priority Pager.
1
3
4 5
8
7
6
2