12.7 Confirm the equipment installed
1. Confirm the type of navigator used with the radar (6000i, etc).
MAKE
MODEL
SERIAL NUMBER
SOFTWARE VERSION
2. Confirm that the NMEA Port 2 interface option is set to RADAR.
3. Confirm the type of radar installed:
• 2 kW dome
• 4 kW dome
• 6 kW open array
• 10 kW open array
• 25 kW open array
4. Make sure the voltage input and radar processor are correct for the system being installed, as
follows:
• 2 kW - 12 V DC - Radar Processor NS004780
• 4 kW - 12 V DC or 24 V DC - Radar Processor NS004781
• 6 kW - 12 V DC or 24 V DC - Radar Processor NS004782
• 10 kW - 24 V DC - Radar Processor NS004783
• 25 kW - 24 V DC - Radar Processor NS004784.
12.8 Are range rings displayed?
Yes, range rings are displayed.
1 Confirm that the installation set up had been performed.
2 Verify that the array is turning. If it is a dome, with the power off, remove the dome cover
(weather permitting). Apply power to the system. After the warm-up countdown has
completed, and the transmit option is set to ON, verify that the array is turning.
3 If the antenna does not turn, skip to the section "If the scanner fails to turn".
No, range rings or range scale information are not displayed.
1 Verify that the serial data cable wiring is correct for the communications cable.