A SERVICE OF

logo

29
MZ-R500/R500PC
71. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
03.
72. Press the X key.
(0D76 is blinking)
73. Press the [VOL+] key to change the blinking portion to 0D78.
74. Press the x key.
(00 is blinking)
75. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
01.
76. Press the X key.
(0D78 is blinking)
77. Press the
[VOL+] key once to change the blinking portion to
0D79.
78. Press the x key.
(00 is blinking)
79. Adjust with the [VOL+] key (adjusted value up) or [VOL--]
key (adjusted value down) so that the adjusted value becomes
E0.
80. Press the X key.
(0D79 is blinking)
81. Press the [T.MARK] key for several seconds (about 3 seconds)
to exit the patch data write mode (to return to the manual mode
display in the test mode).
82. Press the
[ENTER] key and set the address & adjusted value
display (see page 14).
83. Press the X key to write the modified data. (The adjusted value
changes to CC)
84. The modified data writing is over, if the adjusted value changes
to DD.
85. Turn the power off.
This set LCD display
0 2 3 0D7603
03: Adjusted value
This set LCD display
0 2 3
0D7800
00: Adjusted value
This set LCD display
0 2 3
0D7801
01: Adjusted value
This set LCD display
0 2 3 0D7900
00: Adjusted value
This set LCD display
0 2 3 0D79E0
E0: Adjusted value
This set LCD display
0 2 3
Patch
This set LCD display
0 2 3
01: Adjusted value
S01
This set LCD display
0 2 3
DD: Adjusted value
SDD