A SERVICE OF

logo

Secure MICR Printer User’s Guide © Source Technologies
September 2005
39 All Rights Reserved
Audit Report Field Five &%SQ5d..d$
&%SQ5 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the fifth column of the report. This field is a
maximum of eight characters.
Audit Report Field Six &%SQ6d..d$
&%SQ6 Lead in string
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the sixth column of the report. This field is
a maximum of 19 characters.
Audit Report Field Seven &%SQ7d..d$
&SQ&7 Lead in string
d..d Data to be stored
$ Command terminator
This command identifies the data to be printed in the seventh column of the report. This field
is a maximum of 12 characters. The data in this field is recorded for the Audit Report only.
Print and Purge Audit Report &%SPURGExx$
&%SPURGE Lead in string
x option(s)
$ Command terminator
This command prints and purges the Audit Report. All recorded information is deleted. The
optional field can be any combination of the following letters:
T Total Field 4
O Overlay
S Sort by MICR line
C Communicate - send report to host instead of printing - see additional
information below on SPRINT command