A SERVICE OF

logo

INSTALLATION
13.300
Connect gas hob to gas supply
The inlet is at the rear RHS of the hob.
The hob may be connected to the gas
supplyeitherbyrigidpipeworkorexible
connection.
Flexible connections
Use a 900mm - 1125mm length of
exibleconnector.Ensurethatthe
hose is installed hanging freely downwards,
is not trapped, is not subjected
to undue forces and is not supported
at the bottom by a horizontal surface.
Natural Gas - Flexible connections
should comply with BS669, latest edition.
LPGas-Forexibleconnectionsuse
a bayonet type hose, suitable for use
on LP gas up to 50 mbar pressure rise
and70°Ctemperaturerise.Theexible
hose should be coloured black
with a red stripe, band or label. If in
doubt, contact your supplier.
The installation must ensure that the
exibletubecannotcomeintocontact
with movable parts of the housing unit
(eg; a drawer) and does not pass
through any space susceptible to becoming
congested.
Make sure the appliance is gas
sound & all components are
operating correctly.
Connect to the electricity supply
Unless this appliance is supplied with a
ttedplug,itmustbeconnectedbya
competentperson,usingxedwiring
via a double pole switched fused spur
outlet, with a contact separation of 3mm
at all poles.
Connect the mains lead wires to the
terminals:
The blue wire must be connected to the
terminal marked N (Neutral) LOAD or
coloured black. The brown wire must
be connected to the terminal marked L
(Live) LOAD or coloured red.
The green/yellow coloured wire must
be connected to the terminal marked
E (Earth) or coloured green.
Warning: this appliance must be
earthed.
The fused spur must be accessible after
installation.
If the supply cord is damaged, obtain
a special cord from the Customer Care
Helpline,whichmustbettedbya
qualiedperson.