![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/a/8c/a8cda98f-ceeb-46f1-9752-931dc4387f55/a8cda98f-ceeb-46f1-9752-931dc4387f55-bg75.png)
3 - 52
INSP
ADJ
BATTERY INSPECTION AND CHARGING
Å Relationship between the open-circuit voltage
and the charging time at 20 ˚C (68 ˚F)
(These values vary with the temperature, the
condition of the battery plates, and the electro-
lyte level.)
ı Open-circuit voltage
Ç Charging time (hours)
Î Time (minutes)
‰ Charging condition of the battery
Ï Ambient temperature 20 ˚C (68 ˚F)
a Charging
b Check the open-circuit voltage.
5. Charge:
● Battery
(refer to the appropriate charging
method illustration)
WARNING
Do not quick charge a battery.
CAUTION:
● Never remove the MF battery sealing
caps.
● Do not use a high-rate battery charger
since it forces a high-amperage current
into the battery quickly and can cause
battery overheating and battery plate
damage.
● If it is impossible to regulate the charging
current on the battery charger, be careful
not to overcharge the battery.
● When charging a battery, be sure to
remove it from the machine. (If charging
has to be done with the battery mounted
on the machine, disconnect the negative
battery lead from the battery terminal.)
● To reduce the chance of sparks, do not
plug in the battery charger until the bat-
tery charger leads are connected to the
battery.
● Check the charge of the battery, as shown
in the charts and the following example.
Example
Open-circuit voltage = 12.0 V
Charging time = 6.5 hours
Charge of the battery = 20 ~ 30%