56 RXiIIIPlus User Guide 6/21/2004 23063L-001 Rev. 2
Front Panel Controls
Front Panel LCD
APPLICATOR
PORT
Setting the Applicator Port
Determines the action of the verifier port.
Note • Set this value as suggested by the applicator manufacturer.
• Off: The applicator port is off.
• Mode 1: Asserts the ~END_PRINT signal low while the printer is moving the
label forward.
• Mode 2: Asserts the ~END_PRINT signal high while the printer is moving the
label forward.
• Mode 3: Asserts the ~END_PRINT signal low for 20 milliseconds when a label
has been completed and positioned. Not asserted during continuous printing modes.
• Mode 4: Asserts the ~END_PRINT signal high for 20 milliseconds when a label
has been completed and positioned. Not asserted during continuous printing modes.
• Press the right or left oval to display other choices.
Default: Off
Selections: Off, mode 1, mode 2, mode 3, mode 4
START PRINT
SIG
Start Print Signal
This parameter determines how the printer reacts to the Start Print Signal input on pin 3 of
the applicator interface connector at the rear of the printer.
•In Pulse Mode, labels print when the signal transitions from HIGH to LOW.
•In Level Mode, labels print as long as the signal is asserted LOW.
Caution • Start Print Signal is set by the applicator manufacturer and should not be
changed unless the factory defaults have been reloaded. The printer must be returned
to its designated setting for it to work properly.
•Press the right or left oval to display other choices.
Default: Pulse Mode
Selections: Pulse Mode, Level Mode
RESYNCH
MODE
Resynch Mode
This parameter determines how the printer reacts if the label synchronization is lost and the
label top is not where expected.
• Feed Mode—If the label top is not where expected, the printer feeds a blank label
to find the label top position.
• Error Mode—If the label top is not where expected, the printer stops, enters Pause
Mode, displays the message
Error Condition Feed Label
, flashes the
ERROR light, and asserts the Service Required signal (pin 10 on the Applicator
Interface Connector).
To resynch the media to the top of the label in Error Mode, press PAUSE to exit Pause
Mode. The
ERROR light stops flashing, and the Service Required signal is
deactivated. The action of the printer is determined by the
Head Close
configuration selection (see Head Close on page 54).
• Press the right or left oval to toggle between choices.
Default: Feed Mode
Selections: Feed Mode, Error Mode
Table 5 • Printer Parameters (Sheet 13 of 15)
Parameter Action/Explanation