3Com 3C13701 3C13751 3C13755 3C13759 3C13840 3C13880 Network Router User Manual


 
3Com Router 5000 and Router 6000 v2.41
Module Guide
Chapter 3
Multifunctional Interface Modules (Router 5000)
3-27
Table 3-17 Interface attributes of the Router 2 AND 4-Port Enhanced Serial MIM
Description
Attribute
Synchronous Asynchronous
Connector DB-28
Number of connectors
2 (FIC-2SAE)
4 (FIC-4SAE)
8 (FIC-8SAE)
V.24 V.35, RS449, X.21, RS530
Interface standard and
operating mode
DTE, DCE DTE DCE
RS232
Min. baud rate(bps) 1200 1200 300
Max. baud rate(bps) 64 k 4.096 M 2.048 M 115.2
Cable
V.24 (RS232) DTE cable
V.24 (RS232) DCE cable
V.35 DTE cable
V.35 DCE cable
X.21 DTE cable
X.21 DCE cable
RS449 DTE cable
RS449 DCE cable
RS530 DTE cable
RS530 DCE cable
Supported service
1) DDN leased line
2) Terminal access service
1) Dialup through modem
2) Backup
3) Asynchronous leased
line
4) Terminal access
service
3.7.3 Interface LEDs
The following figures show the 2 and 4-port panels: