AC International CT0-7TC-32 Switch User Manual


 
ADVANCED SETTINGS - DUAL FUEL SWITCH
33INSTRUCTION MANUAL
! IMPORTANT: This feature can only be activated when used with the Climatouch
Outdoor Wireless Temperature Transmitter and Receiver. Please install the
Climatouch
Outdoor Wireless Temperature Transmitter and Receiver before
activating this feature.
Increasing energy efficiency and reducing costs can be achieved by using the
dual fuel switch. Your heat pump can generally provide heat and comfort without
assistance to an outside temperature of just a few degrees below freezing. This
temperature is called the heat pump balance point. When the outside temperature
is above the balance point, the heat pump alone is sufficient for heating.
Once the outdoor temperature drops to the balance point the heat pump must
be assisted by your alternate energy source. When the outdoor temperature
drops below the systems normal crossover temperature (-12°C or -15°C), your
heat pump will stop operating and the alternate energy source will take over.
:: HP Cut ON or OFF
:: Cut Temperature:
+/-Temperature in Celsius (-5°c to 25°c)
+/- Temperature in Fahrenheit (13°F to 41°F)
1
Available only in combination with WIRELESS OUTDOOR TEMPERATURE TRANSMITTER AND RECEIVER KIT (90064)
ADVANCED SETTINGS - SYSTEM CONFIGURATION
32 Climatouch
CT0-7TC-32
! IMPORTANT: By inadvertently modifying system configuration settings, you
may seriously degrade HVAC system performance.
>>Choose system heating and cooling equipment - remember all you need to do
is toggle the appropriate button until the correct setting appears.
:: Choose HEAT PUMP or 2 STAGE HEAT PUMP or AIR CONDITIONING or NO
COMPRESSOR - please review the wiring table and diagram for wiring instructions.
:: Choose FURNACE OFF (No Furnace) or ELECTRIC FURNACE or EMERGENCY
ELECTRICAL FURNACE(additional electric furnace which will come on in emergency
mode in conjunction with electric furnace) or GAS FURNACE or OIL FURNACE or
2 STAGE GAS FURNACE; please review the wiring table and diagram for wiring
instructions.
:: CYCLE RATE: Set Maximum compressor cycles per hour. We recommend that the
factory default be maintained for optimal performance..
:: AUTO CHANGE: Set the minimum difference between Auto Mode, Heat and Cool
temperature setpoints. We recommend that the factory default be maintained
for optimal performance.