Accton Technology ES3628EA Switch User Manual


 
4-3
Fiber Optic SFP Devices
4
Fiber Optic SFP Devices
An optional SFP transceiver (100BASE-FX, 1000BASE-SX, 1000BASE-LX or
1000BASE-LH) can be used for a backbone connection between switches, or for
connecting to a high-speed server.
Each multimode fiber optic port requires 50/125 or 62.5/125 micron multimode fiber
optic cabling with an LC connector at both ends. Each single-mode fiber port
requires 9/125 micron single-mode fiber optic cable with an LC connector at both
ends.
Warning: This switch uses lasers to transmit signals over fiber optic cable. The lasers are
compliant with the requirements of a Class 1 Laser Product and are inherently
eye safe in normal operation. However, you should never look directly at a
transmit port when it is powered on.
Note: When selecting a fiber SFP device, considering safety, please make sure that it
can function at a temperature that is not less than the recommended maximum
operational temperature of the product. You must also use an approved Laser
Class 1 SFP transceiver.
Hinweis: Bei der Wahl eines Glasfasertransceivers muß für die Beurteilung der
Gesamtsicherheit beachtet werden, das die maximale Umgebungstemperatur
des Transceivers für den Betrieb nicht niedriger ist als die für dieses Produkts.
Der Glasfasertransceiver muß auch ein überprüftes Gerät der Laser Klasse 1
sein.
4. Check that the fiber terminators are clean. You can clean the cable plugs by
wiping them gently with a clean tissue or cotton ball moistened with a little
ethanol. Dirty fiber terminators on fiber cables will impair the quality of the light
transmitted through the cable and lead to degraded performance on the port.
5. Connect one end of the cable to the LC port on the switch and the other end to
the LC port on the other device. Since LC connectors are keyed, the cable can
be attached in only one orientation.
Figure 4-3 Making LC Port Connections