Acer 5730Z/5330 Laptop User Manual


 
Chapter 5 119
Clearing Password Check and BIOS Recovery
This section provide you the standard operating procedures of clearing password and BIOS recovery for
Aspire 5730Z/5330 Series. Aspire 5730Z/5330 Series provide one Hardware Open Gap on main board for
clearing password check, and one Hotkey for enabling BIOS Recovery.
Clearing Password Check
Hardware Open Gap Description
HW Gap position on M/B space:
Gap name in Aspire 5730Z/5330 Series is G10
Steps for Clearing BIOS Password Check
If users set BIOS Password (Supervisor Password and/or User Password) for a security reason, BIOS will ask
the password during systems POST or when systems enter to BIOS Setup menu. However, once it is
necessary to bypass the password check, users need to short the HW Gap to clear the password by the
following steps:
Power Off a system, and remove HDD, AC and Battery from the machine.
Open the back cover of the machine, and find out the HW Gap on M/B as picture.
Use an electric conductivity tool to short the two points of the HW Gap.
Plug in AC, keep the short condition on the HW Gap, and press Power Button to power on the
system till BIOS POST finish. Then remove the tool from the HW Gap.
Restart system. Press F2 key to enter BIOS Setup menu.
If there is no Password request, BIOS Password is cleared. Otherwise, please follow the steps and
try again.
NOTE: The steps are only for clearing BIOS Password (Supervisor Password and User Password).
Hardware Default Setting Operation Description
Gap Open (Normal) Short (Clearing Password Check)