ACS MPS Paper Shredder User Manual


 
GRN4-610 Chapter 2: Functional Description 31 of 73
broken. If the housing flap will be opened during operation, the safety switch is
activated, thus switching off the machine.
"V"-belts and pusher protector
"V"-belt and pusher protection are fixedly connected to the machine. They can be
dismounted for installation and maintenance work. However, this may only then be
carried out when all rotating parts have come to a complete standstill.
Illustration:
V-belt cover
Pusher cover
If machines are delivered on the request of the customer without drive motors,
the operator is obliged to fit and mount the protective devices delivered together
with the machine himself in line with the current legal safety regulations.