ACTiSYS ACT-IR100S Network Card User Manual


 

"#+
PC#1:
Install IrDA Driver. The assigned IR virtual port must be COM4 or less, otherwise HyperTerminal
will not be able to connect it
IR Monitor: Speed limit = 115.2K or lower
HyperTerminal: Connect Using -> direct to COM4 (assigned virtual port of IR)
PC#2:
100S:
R11-18 or DSW8-1: 1100, 0111
Primary/Secondary, 9.6k, Self channel setting, 8-N,
HyperTerminal: Connect Using -> direct to COM1 or COM2 (the port IR100S using)
9.6k, 8-n-1, Hardware flow-control
&-
1. Connect all devices as FigA-1
2. Switch on PC#2 and the power supply of 100s.
3. Run HyperTerminal on PC#2. Set its properties according to the above configuration guide (Fig
A-2 ..4).
The LED DTR and RTS of the RS232 Mini Tester should be Red (True) when it is connected. The
DTR will go to Green (False) if you disconnect it. When both DTR and RTS are True (high level) the
100S will begin discovery if you set it to Primary or Primary/Secondary. The 100S' LED will blink once
every 3 seconds.
4. Switch on PC#1.
You will see the IR Found icon and hear the sound of found IR device when windows has started.
Open the IR Monitor, you will see the Status are:








 
!"
#
$%&$
''
()
        
)!*+
,-) ,-
