ADC DL3XR-FCA100 Network Card User Manual


 
Local Configuration LTPS-UM-8013-03
30 August 30, 2002 D3LX CO and RMT Modules
PERFORMING SYSTEM MAINTENANCE
Use this procedure to perform the system maintenance commands
listed.
1 From the Main menu, select 6. System Maintenance.
2 From the System Maintenance menu, select
1. Force/APS Commands, and then select
1. Commands for Optical Facilities to view
and force line protection for the available circuits,
2. Reset/LED Test Commands to reset the selected
D3LX module or verify that its LEDs are working properly,
4. Loopback Status Commands, and then select 1,
High/Low Speed Loopback Status/Commands
to view the loopback status or perform loopbacks on the
selected D3LX, or
8. Trouble Isolation (as shown in Figure 18 on
page 31), and then select the Group and Slot.
3 Use , , , ,
and to select the group and slot to
display, populate each data field according to your requirements,
then assign the selections by pressing .
6. System Maintenance
1. Force/APS Commands
2. Reset/LED Test Commands
3. Execute ACO (Alarm Cut-Off)
4. Loopback Status/Commands
5. Display Inventory
6. Display Circuit IDs
7. SCU-860 Data Transfer
8.Trouble Isolation
9. Metallic Loop Qualification
(MLQ Capable Chassis Required)
SPACEBAR
ENTER