ADTRAN 4110 Network Router User Manual


 
Chapter 3. Terminal Menu Operation and Structure
61200176L3-1 Express 4110/4120 User Manual 3-49
PPP/Max Failure
Write security: 3; Read security: 5
Due to the nature of PPP, configuration options may not be agreed upon
between two PPP peers. This value is the number of configuration-naks
that should occur before an option is configuration-rejected. This allows
a connection to succeed that might otherwise fail. The possible values are
5 (def), 10, 15 and 20.
Connection List/Dial Out
The dialing parameters for establishing this connection are defined under
this menu.
Dial Out/Number 1
Write security: 3; Read security: 5
This is the first number used for dialing up this connection.
Dial Out/Number 2
Write security: 3; Read security: 5
This is the second number used for dialing a second B-channel when
adding bandwidth. If BACP/BAP is negotiated, this number is not nec-
essary. If this number is not specified and BACP/BAP is not used, the
Number 1 number is re-dialed when adding bandwidth.
Dial Out/Call Type
Write security: 3; Read security: 5
The call type can be configured in four different ways:
Speech
Speech directs the call control software to request a
Mu-law encoded speech circuit as the bearer capabil-
ity for the outgoing calls. The speech option is used
with an ISDN line configured for voice service. In
some areas, voice service costs less than data ser-
vices. A speech call type does not always guarantee
an end-to-end digital connection with some local and
long distance carriers.