AGFA M4F Printer User Manual


 
Global Services North America
Wilmington MA 01887
Site Readiness Check List
Information to Check
Yes
No
Lateral fork movement capability. Proper lifting rating? (Pg.4)
Forklift
Length of forks should be 60 inches (152.4cm) minimum
Loading Dock If the customer does not have a loading dock, then the freight truck
delivering the Anapurna will need a lift gate to lower the crate to the ground
along with the forklift
3 - 5 HP, 60 - 80 gallon or better Capacity Compressor?
24/7 operation if required. The compressors regulator should be set to 105 -
110 PSI for trip OFF and to 85 PSI to trip ON. See (pg . 6) Engine air
volume is .28 CFM
Air filtration for moisture and particles?
Compressed Air
Supply
Air regulator for the engine?
Humidity
Range 35% to 75% RH (non-condensing) Ideal 40% ?
Air
Temperature
Not to exceed 126º F or 52 ºC
Room
Temperature
Range 68° F to 80° F (20 – 26.6° C) Ideal 72° F (22° C) ?
Room air exchange should be 10 times per hour ? page 14
RIP Computer
Specs Met?
Refer to page 7 for details. Windows Vista operating system can not be
used.
208 Y (Wye), Single Phase, 60 Hz, 40 Amp
40 amp breaker circuit?
Dedicated Circuit?
Line voltage for
engine
A Buck/Boost transformer maybe required to bring the voltage up to 230 -
240 VAC Range.
See page 9.
Floor should be concrete, flat and stable? No Carpet Allowed
Floor area
156 lbs/ft² (70 kg/m²) Per foot load on the floor.
Work Space: 500 cm x 550 cm (16.4 feet x 18.1 feet)
Check for clearance (uncrated). No less than 7 foot or 213 cm high. (Pg.4)
Check doorways for clearance (height, width)
Ceiling Height
Check path from loading dock to installation location
Is there room for the removal and replacement of parts for servicing? (Pg. 5)
System
Orientation
Can all engine doors open fully?
Head Wipes Customer informed of proper heads wipes required? (Pg 14)
Questions? Contact 800-879-2432 and ask for an Anapurna Specialist
12