AGFA M4F Printer User Manual


 
Global Services North America
Wilmington MA 01887
General Information
Environmental Requirements
Room Operating Temperature: Range 68° F to 83° F (20 - 28° C) Ideal 72° F (22° C)
(Room air temperature should not to exceed 126º F or 52 ºC)
Humidity: Range 35% to 75% RH (non-condensing) Ideal 40%
Room Air Exchange: 10 times per hour.
The room must be clean and dust free so that no contamination can adversely affect the print heads and print quality.
Manual Load or Roll feed Rigid materials loaded by hand, or roll to roll material
Printer Resolution: 720 x 720 dpi (4 Pass) and 720 x 1440 dpi (8 Pass)
Manual unload or Roll feed Material exits on the table or can be automatically rolled up.
Air Internally regulated to control ink flow and pneumatics
Vacuum A ring blower is used to generate vacuum for the feed table.
Ventilation Room air exchange is required, 10 times per hour.
Software RIP Wasatch RIP Includes dongle, software and installation key.
Heads Konica Minolta 512 Nozzles, 14 pl
Ink Curing Two UV curing lamps
Inks UV curable: Anapurna inks, four ink tanks (K, C, M, Y)
Media Media Width: up to 160 cm (63 inch) Printable width: up to 158 cm
(62 inch) [Borderless 152 cm (60 inch)]
Maximum Roll media weight: 50 kg
or 110lbs Minimum thickness = 1mm and maximum thickness = 45 mm
Printing Speed 4 Pass Bi directional 13.8 m²/hr (149 ft2/hr)
4 Pass Uni directional 8.1 m²/hr (87 ft2/hr)
8 Pass Bi directional 7.5 m²/hr (81 ft2/hr)
8 Pass Uni directional 4.0 m²/hr (43 ft2/hr)
Engine AC Voltage Single phase power 208 Y, 60HZ, with a 230 – 240 Voltage range is
required with ground no neutral, 40 Amp dedicated circuit. Buck/Boost
transformer may be needed the 208 Y power to the 230 – 240 Volts range.
Head Wipes Do not use cotton, poly or silk material on print heads, Agfa recommends:
Company: Harmony Business Supplies (www.harmonycr.com)
Phone Number: 800- 899-1 255
Product Code: CT 604
Description: Pre Cut 4” x 4”, Hydrosorb 1 Wipes, 1200/Bag
Cost: A
p
p
roximatel
y
$
30.00
Questions? Contact 800-879-2432 and ask for an Anapurna Specialist