Agilent Technologies 664xA Power Supply User Manual


 
Language Dictionary 49
Programming Parameters
Table 3-1 list the programming parameters for each of the models.
Table 3-1. Power Supply Programming Parameters (see note)
Parameter Agilent Model and Value
CURR[:LEV] MAX and
6641A
6642A 6643A 6644A 6645A
CURR[:LEV]:TRIG MAX 20.475 A 10.237 A 6.142 A 3.583 A 1.535 A
(Programming range is 0 to MAX)
6651A
6652A 6653A 6654A 6655A
51.188 A 25.594 A 15.356 A 9.214 A 4.095 A
6671A 6672A 6673A 6674A 6675A
225.23 A 102.37 A 61.43 A 35.83 A 18.43 A
6680A 6681A 6682A 6683A 6684A
895 A 592 A 246 A 164 A 131 A
6690A 6691A 6692A
450 A 225 A 112 A
*RST Current Value
6641A
6642A 6643A 6644A 6645A
0.08 A 0.04 A 0.024 A 0.014 A 0.006 A
6651A 6652A 6653A 6654A 6655A
0.205 A 0.100 A 0.060 A 0.036 A 0.016 A
6671A 6672A 6673A 6674A 6675A
2.65 A 0.40 A 0.24 A 0.14 A 0.07 A
6680A 6681A 6682A 6683A 6684A
73.71 A 48.75 A 20.26 A 13.51 A 10.79 A
6690A 6691A 6692A
37.06 A 18.53 A 9.26 A
OUTP:PROT:DEL
*RST Value
0 to 32.727 s (MAX) for all models
200 ms for all models
VOLT[:LEV] MAX and
6641A 6642A 6643A 6644A 6645A
VOLT[:LEV]:TRIG MAX
6651A 6652A 6653A 6654A 6655A
(Programming range is 0 to MAX)
6671A
6672A 6673A 6674A 6675A
8.190 v 20.475 V 35.831 V 61.425 V 122.85 V
6680A 6681A 6682A 6683A 6684A
5.125 V 8.190 V 21.50 V 32.75 V 41.0 V
6690A 6691A 6692A
15.375 V 30.75 V 61.5 V
*RST Voltage Value 0 V for all models
VOLT:PROT MAX
6641A 6642A 6643A 6644A 6645A
(Programming range is 0 to MAX)
6651A
6652A 6653A 6654A 6655A
8.8 V 22.0 V 38.5 V 66.0 V 132.0 V
6671A 6672A 6673A 6674A 6675A
10.0 V
24.0 V 42.0 V 72.0 V 144.0 V
6680A 6681A 6682A 6683A 6684A
6.25 V 10.0 V 25.2 V 38.4 V 48.0 V
6690A 6691A 6692A
18 V 36 V 69 V
*RST OVP value
MAX for all models
Note For programming accuracy and resolution, see the Specifications and Supplemental