GSM System 4
N9360A Multi UE Tester Quick Reference Guide 4-7
Press the Trigger Sing/Cont softkey again to terminate the
continuous measurement.
9 In the graphical display, the marker function is available to
read the data points by rotating the knob. On the power ramp
graph display, the zoom function is also available.
10 To display other measurement result screens, press the
Return softkey to display the previous screen. To end the
entire test, press the Release softkey to start the BS Release,
or press the On Hook key on the mobile phone to finish the
MS Release.
RF Channels
MS Power Control / Power Class
Table 4-3 GSM RF channel frequencies and channel number
GSM850 GSM900 DCS1800 PCS1900
Uplink 824.2 to 848.8 MHz 890.2 to 914.8 MHz
876.2 to 889.8 MHz
1710.2 to 1784.8 MHz 1850.2 to 1909.8 MHz
Downlink 869.2 to 893.8 MHz 935.2 to 959.8 MHz
921.2 to 934.8 MHz
1805.2 to 1879.8 MHz 1930.2 to 1989.8 MHz
ARFCN 128 to 251 0 to 124
955 to 1023
512 to 885 512 to 810
NOTE
GSM900 includes P-GSM, E-GSM, and R-GSM Bands.
Table 4-4 GSM Power Control levels
GSM 850 / 900 DCS1800 PCS1900
Power Control
Level
Nominal Power
(dBm)
Power Control
Level
Nominal Power
(dBm)
Power Control
Level
Nominal Power
(dBm)
0 39 2936 3033
3 37 3034 3132
435 3132 030
533 030 128
631 128 226