Agilent Technologies N9360A Network Router User Manual


 
W-CDMA System 5
N9360A Multi UE Tester Quick Reference Guide 5-3
For Pinpointing Failures
Figure 5-2 [Automatic Test: Stand-by] Screen
1 Perform the steps described in “For Go/No-Go Testing.”
2 Press the Screen>> softkey to set screen mode to Value.
3 Check the values of the measurement results.
Table 5-1 W-CDMA Automatic Test Sequence
Step Action needed
Location Update Wait until the Location Update is completed.
MS Call Dial an arbitrary number and press the Off Hook key
on the mobile phone.
Talk Talk to the mobile phone to judge its loop back sound
quality and press the Pass or Fail softkey.
MS Release Finish the call from the mobile phone.
BS Call (AMR) Respond to the call on the mobile phone.
BS Call (RMC) The mobile phone automatically responds to the call.
RF Test Wait until the RF test is completed.
BS Release Wait until the call is finished from the Tester.